Automatic Change Over Manifold System

Automatic Change Over Manifold System
Automatic Change Over Manifold System
Send Inquiry
Product Code : ACOMS-10
Brand Name : ATHENA TECHNOLOGY
Product Description

Automatic Change Over Manifold System

High pressure Mechanical-Automatic Gas Change Over Manifold  System

High pressure Mechanical- Automatic Gas  Manifold is used for two cylinder system where automatically switching over is required from one cylinder to other, when the pressure in the one cylinder is below the set pressure. Setting of pressure of two cylinder can be set   as per user requirement ( Refer Setting Procedure ) .

 Specs

Inlet Pressure Gauge         :   2 nos. of 0 – 210 Kg Gauge.

Outlet Pressure Gauge      :   1 no. of 0 – 14 Kg Gauge.

Flow                                       :    300 LPH (MAX)

Gas services                         :    Air ,N2, H2 ,He, Ace,

                                                     Arg ,N2o,P10 and other gas

 Outlet Connection              :    ¼”OD ferrule fitting with ball valve

Inlet connection                 :    1/4:” BSP male to suit   pigtail

Size                                         :    H 38 mm X D 235 mm X L 500 mm

                                                     Mounting Dimension: 

Setting Procedure :

1)     Connect both cylinders  with flexible pigtails

2)     Open the cylinder 1 and apply the pressure of Cylinder 1 ( Line 1) to the manifold

3)     Set the  pressure through cylinder 1 regulator ( e.g.  7 kg)

4)     Open the cylinder 2 and apply the pressure of cylinder 2 ( Line 2 ) to the manifold.

5)     Set the pressure through cylinder 2 regulator ( e..g. 6 Kg.)

6)      Set the outlet pressure as per requirement With outlet press Regulator

 

7)     Open outlet valve to use as per  requirement
8)      Vent valve 1 and vent valve 2 is use to purge vent the gas Cylinder change  Procedure  :- if cylinder1cylinder got  empty close  the shutt off vale  replace Cylinder with  filled cylinder  open the vent valve for few seconds to purge and close the valve  repeat same procedure  for cylinder 2 if .it get empty 

With years of modern experience, we being a prominent exporter, manufacturer, and supplier are introducing a subjective accumulation of Automatic Change Over Manifold System. We make this complex framework by utilizing the best quality raw material and front line innovation in adherence with industry standards. Our quality specialists test this complex framework on shifted parameters in order to keep up its quality. In addition to this, customers can profit this Automatic Change Over Manifold System from us in variegated outlines and determinations.


Features:

  • Smooth completion
  • Effective execution
  • Tough development

ATHENA TECHNOLOGY
X


Contact Details
  • ATHENA TECHNOLOGY
  • 802, Hercules, Lodha Paradise, Majiwada, Thane (W), Thane - 400601, Maharashtra, India
  • Phone : +918061857273
  • Send Inquiry Send SMS
  • Mrs. Milan Salunke (Director)
  • Mobile : +918061857273
  • Send Inquiry
ATHENA TECHNOLOGY All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Ltd.